Fortec
Fortec Stabilization Systems
Carbon Fiber Technologies
Questions? Call Us
1-800-207-6204

Versión de Español
Case Studies

Date:April, 2012
Location: I-75 & 12 Mile Rd in Sterling Heights MI
Contractor: Smith's Waterproofing
Engineer: Michigan Department of Transportation
Material Used: Fortec 600 gsm unidirectional carbon fiber fabric w/ #4550 Epoxy Saturant and #590 Epoxy paste
Project Scope:
Concrete Columns were deemed to be fatigued due to deterioration of steel reinforcement. Repair was to wrap columns using 600 gsm carbon fiber wrap utilizing onsite impregnator of epoxy saturant.

Bridge Column Repair Bridge Column Repair


Conclusion:
Wrapping column with Fortec carbon fiber fabric allowed for minimal road closure as would have been needed with old method of teardown and replacement of column. The #4550 epoxy allowed contractor to cure out in field under difficult weather conditions. With highs in the 60's and lows dipping into the 40's a night curing was a challenge.




HOME | ENGINEERING TIPS & DESIGN | PRODUCTS & SPECIFICATIONS | PROJECTS & CASE STUDIES | ABOUT Fortec | CONTACT FORTEC

© Copyright 2010 Fortec Stabilization Systems
All Rights Reserved.

Fortress Stabilization products are protected by the following patents: 7,823,354 (Structure reinforcement system); 7,743,585 (Structure reinforcement system); RE39,839 (Carbon Fiber reinforcement system); 6,846,537 (Carbon fiber reinforcement material); 6,746,741 (Carbon Fiber reinforcement system); 6,692,595 (Carbon Fiber reinforcement Systems); and other pending patents.